ASTM D6927 PDF

Test Procedure of ASTM D – 06 Standard Test: The apparatus for the Marshall Stability test consists of the following: Specimen mould assembly comprising. ASTM DStandard Test Method for Marshall Stability and Flow of Bituminous Mixtures_建筑/土木_工程科技_专业资料。ASTM的沥青混合. Preparation of Marshall Specimens (from bituminous mixes). ASTM D PROCEDURE (continued) e. Specimens conditioned to specified temperature.

Author: Zolokus Vijind
Country: Somalia
Language: English (Spanish)
Genre: Art
Published (Last): 5 October 2009
Pages: 79
PDF File Size: 5.93 Mb
ePub File Size: 11.68 Mb
ISBN: 206-9-46927-664-2
Downloads: 94000
Price: Free* [*Free Regsitration Required]
Uploader: Kigagul

One test result is considered to be the average of tests on three specimens.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, xstm entirely their own ast. Typical Cross Section of Highways Roadways. Stability, flow, density, air voids, and voids filled with asphalt binder, may be plotted d697 binder content to allow selection of an optimum binder content for the mixture.

For the purpose of mix design, Marshall stability and flow test results should consist of the average of a minimum of three specimens at each increment of binder content where the binder content varies in one-half percent increments over a range of binder content. Link to Active This link will always route to the current Active version of the standard. This test method is for use with dense graded asphalt mixtures prepared with asphalt cement modified and unmodifiedcutback asphalt, tar, and tar-rubber with maximum size aggregate up to 1 in.

In addition, a mixture design may be required to meet minimum voids in the mineral aggregate based on nominal maximum aggregate size in the mixture. The firmware allows performance of transducer calibrations and setting of up to 10 test profiles, saving data onboard. The above test properties may also be weighted differently to re?

NOTE 1—A higher capacity ring dynamometer may be required for high-stability mixes. In both types of failure, the Marshall? It is the responsibility of the user asrm this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  FINK UVOD U FILOZOFIJU PDF

Stay informed – subscribe to our newsletter. d692

The magnitude of Marshall Stability varies with aggregate type and grading and bitumen type, grade and amount. The binder content range is generally selected on the basis of experience and historical testing data of the component materials, but may involve trial and error to include the desirable range of mix properties.

Marshall stability and flow may also be used to relatively evaluate different mixes and the effects of conditioning such as with water. The source of astj variation should be resolved and the problem corrected.

The EN covering the Determination of the indirect tensile strength of bituminous mixtures, prescribe a water Dense-graded mixtures will generally show a peak in stability within the range of binder contents tested.

ASTM D6927 – 15

Different asphalts were also used. There is no ideal value but there are acceptable limits.

Bring specimens prepared with asphalt cement, tar, or tar-rubber to the speci? Popular in this Category. The machine is supplied complete with load ring, 30 kN cap.

The machine is fit with a precision strain gauge load cell and displacement transducer, both connected to the Digimax A real-time test graph and transducer data are displayed on the touchscreen. The specimens should have the same aggregate type, quality, and grading; wstm same mineral?

The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

ASTM DStandard Test Method for Marshall Stability and Flow of Bituminous Mixtures_图文_百度文库

These results are given in percent so that they apply to various levels of Marshall stability and? The coefficients of variation and acceptable range of two results are the average of the four sets of pro? Circulating water bath with cooler unit for Marshall.

As shown in Fig. These devices must be designed to measure and record the same relative movement between the top of the guide d692 and the upper breaking head. The Marshall Test can be conducted with two different types of equipment: The large acceptable range of two test results aatm indicates that this test should not be used for material acceptance programs that compare between-laboratory results.

  ASTM A179 PDF

These results do not include application of the density limitation in Test Method D Your comments will receive careful consideration at a meeting of asstm responsible technical committee, which you may attend.

ASTM D Standard

All the accessories have to be ordered separately. The front panel is fitted with an emergency button for prompt stopping of the machine. However, depending on the composition and behavior of the mixture, a less defined type of failure has been observed, as illustrated in Fig.

Reliable results depend on many factors; following the suggestions of Specification D or some similar acceptable guideline provides a means of evaluating and controlling some of those factors. If a water bath is used, wipe excess aetm from the inside of the testing head segments. D — 05 TABLE 1 Stability Correlation FactorsA Volume of Specimen, cm3B to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to to A 8.

Marshall compression tester A bench mounted compression frame with motor and worm gear housed within the base unit. Last previous d69227 approved in as D — Maintenance Spares Technical trainings Warranty Academy. The binder content range is generally selected on the basis of experience and historical testing data of the component materials, but may involve trial and error to include the desirable range of mix properties.